SDO2072 Oscilloscope Numérique 2 Voies 70MHZ
66 000
DA
FixeDescription de l'annonce
Numéro
40403540
Date
11/06/2024 14:44:56
Vues
156
Référence
SDO2072
Etat
Neuf jamais utilisé
Marque
MCP
Description
Features
. 70MHz/100MHz/150MHz/200MHz bandwidth
. Independent double time base
. AUTO’s strategy presetable
. Lissajous figure supported
. Automatic measurement of 34 waveform parameters
. Automatic cursor tracking measurement function
. 2 channels, low noise floor, wide vertical range: 1mV/div~20V/div
. Built in FFT and digital filter
. System software upgrade via USB drive
. 7 inches TFT LCD,high resolution display 800×480
. Delicate window extension function and precise analysis on waveform details and overview
. Supports plug-and-play USB storage device; communication with and remote control of computer through the USB device
Technical Data SDO2072 SDO2102X SDO2152 SDO2202X
Real-time Sample Rate 500MS/s 1GS/s 500MS/s 1GS/s
Equivalent Sampling Rate 50GS/s 50GS/s 50GS/s 50GS/s
Average Sampling Times 2, 4, 8, 16, 32, 64, 128 and 256
Input Channel Specifications
Input coupling DC, AC, GND
Input Impedance (1MΩ±2%)//(18pF±3pF)
Probe attenuation coefficient
0.01×/0.02×/0.05×/0.1×/0.2×/0.5×/1×/2×/5×/10×/20×/50×/100×/200×/500×/1000×
Maximum input voltage 300 Vrms,the transient over voltage is 1000 Vpk.
Horizontal System Specification
Time-base scale 2ns/div-50s/div
Waveform interpolation Sin(x)/x
Time-base accuracy ≤±(50 + 2×service life)ppm
Record length 2×512k sampling point
Storage depth Single channel: 64kpts;Double channel: 32kpts
Sampling rate and delay time accuracy ±50ppm (any time interval≥1ms )
Measurement accuracy of time interval (△T)
Single : ±(1 sampling time interval + 50ppm x reading + 0.6ns)
>16 average values: ±(sampling time interval+50ppm×reading+0.4ns)
Waveform capture rate 5,000 wfms/s
Vertical System Specification
Analog Bandwidth 70MHz 100MHz 150MHz 200MHz
Rise Time(Typical) ≤7ns ≤3.5ns ≤2.4ns ≤1.8ns
Channels 2 2 2 2
Analog-to-digital converter (A/D) 8 bits 8 bits 8 bits 8 bits
Deflection factor range 1mV/div~20V/div(1MΩ)
Position range ≥±8div
Selectable bandwidth limitation (Typical) 20MHz
Low frequency response (AC Coupling, -3dB)
≤5Hz(above BNC)
DC gain accuracy 5mV~20V/div:≤±3%, 1mV~2mV/div:≤±4%
DC measurement accuracy
When vertical position is 0 and N≥16:
± (4%×reading+0.1div+1mV) and selects 1mV~2mV/div;
± (3%×reading+0.1div+1mV) and selects 10mV~20V/div
When vertical position is not 0 and N≥16:
±(3%×(reading + vertical position reading) + (1%×vertical position reading)+0.2div);
The setting from 5mV/div to 200mV/div plus 2mV, the setting value from 200mV/div to 20V/div plus 50mV
Measurement accuracy of
voltage difference (△V)
(average sampling mode)
Under the same setting and environment conditions and after averaging the captured waveforms with a quantity of ≥16, the voltage difference (ΔV) between any two points on
the waveform: ±(3%×reading+0.05div)
Trigger System Specification
Trigger sensitivity ≤1div
Range of trigger level Int:From the screen center ±10div;Ext:±3V
Trigger level accuracy (typical)
(Signal with rising and falling time≥20ns)
Int:±(0.3div×V/div) (within±4 div from the screen center)
Ext:±(6% setting value+40mV)
Pre-trigger capacity
Normal mode/scan mode, pre-trigger/delay trigger
the pre-trigger depth is adjustable
Hold-off range 80ns~1.5s
Set the level to 50% (Typical) Operate under the condition of input signal frequency of ≥50Hz
Trigger mode Auto, Normal, Single
High-frequency hold off Hold off signals over 80kHz
Low-frequency hold off Hold off signals below 80kHz
Measurements
Cursor Manual mode
Voltage difference between cursors (△V),
Time difference between cursors (△T),
Reciprocal of △T (Hz) (1/△T)
Track mode Voltage value and time value of point of waveform
Auto mode Cursor display is allowed on auto measurement mode
Automatic measurement
Vpp,Vamp,Vmax,Vmin,Vtop,Vbase,Vmid,Average,Vrms,Overshoot,Preshoot,
Frequency,Period,RiseTime,FallTime,+Width, -Width,+Duty,-Duty,Delay,
FRFR,FFFR, FFFF, FRLF, FRLR,FFLR,FFLF
Measurement quantity Display 5 types of measurement at the same time
Measurement scope Screen or cursor
Measurement statistics Average value, maximum value, minimum value and standard deviation
Math
Math operation +, -, ×, ÷
Vertical scale Rectangle, Hanning, Blackman, Hamming
Digital filtering Vrms, dBVrms
Low pass, High pass, Band pass, Band reject Low pass, High pass, Band pass, Band reject
Trigger frequency meter
Reading resolution 6bits
Trigger sensitivity ≤30Vrms
Accuracy (Typical) ±51ppm (+1 character)
Storage Internal: 20 groups. USB: 200 groups
Display 7-inch 800X480 color LCD
Interface Standard: USB Host, USB Device, EXT Trig,Pass / Fail. Option: LAN
Power 100V~240VACrms,50/60Hz,CAT II
Size 306mm(W)×138mm(H)×124mm(D)
Weight 2.5kg
Questions & Réponses
Aucun commentaire pour cette annonce